Korean J. Vet. Serv. 2022; 45(3): 243-248
Published online September 30, 2022
https://doi.org/10.7853/kjvs.2022.45.3.243
© The Korean Socitety of Veterinary Service
Correspondence to : Young-Wook Kim
E-mail: kimyu1223@korea.kr
https://orcid.org/0000-0003-0498-6594
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0). which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
The HPLC conditions for analysis of ivermectin in solutions dosage forms of commercial anthelmintics are different for each product. The purpose of this study was to establish a standardized chromatographic method for the quantification of ivermectin in solution. The separation was achieved on Waters Xbridge C18 column (4.6×150 nm, 5 μm) using different kinds of mobile phase composed of water/methanol/acetonitrile (15/34/51, v/v and 19.5/27.5/53, v/v), with UV detection at wavelengths 245 nm and 254 nm. A total of five commercial ivermectin in solution samples were analyzed. In this study, the optimal chromatographic conditions for analysis of ivermectin in solution were mobile phase of water/methanol/acetonitrile (15/34/51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters Xbridge C18 column (4.6×250 nm, 5 μm) at a column temperature of 25℃. The linearity was observed in the concentration range of 50∼150 μg/mL, with a correlation coefficient, r2=0.99999. The limit of detection and the limit of quantification were 0.88 and 2.68 μg/mL, respectively. The accuracy (% recovery) was found to be 98.9 to 100.3%. Intraday and Intermediate precisions with relative standard deviations were less than 1.0%. The content of ivermectin for five market samples ranged 91.2∼102.7%. The proposed method was also found to be robust, therefore, the method can be used for the routine analysis of ivermectin in solutions dosage forms.
Keywords Ivermectin, Veterinary, HPLC, Validation
Ivermectin (5-O-dimethyl-22,23-dihydroaverrmectin) is an antiparasitic and anthelmintic agent that kills various parasites such as lice, mange and wireworms etc (Waldia et al, 2008; Patel et al, 2015). It has been used in domestic animals for treatment of endoparasites and ectoparasites (Bark et al, 2007; Rao et al, 2017). Many analytical methods including thin-layer chromatography (TLC), high performance liquid chromatography (HPLC), high performance liquid chromatography with mass-spectrometry (HPLC-MS) or tandem mass spectrometry (MS/MS) have been developed for the analysis of ivermectin (Waldia et al, 2008). Ivermectin can be administered orally, subcutaneously, intramusculary and applied to the skin (Bark et al, 2007). Ivermectin in solution dosage form applied to the skin is easy to use in livestock farms and its use is increasing day by day (Bark et al, 2007). Currently, there are 11 ivermectin topical solutions from 11 companies registered with the Animal Drug Associations (based on sales performance from 2010 to 2019). All 11 products use HPLC to quantify ivermectin. However, the HPLC conditions such as mobile phase, flow rate and wavelength are different for each product, quality control is not performed with the same test method.
Therefore, we aimed to establish a standardized chromatographic method for the quantification of ivermectin in solution and validate the established assay.
Agilent 1260 Infinity II series HPLC system equipped with a model G7111A pump, a model G7129A autosampler, a model G7117C UV-detector and Chemstation Software (Version Rev C.01.10 (236)) were used.
Ivermectin was purchased from the United States Pharmacopeia (USP) (Rockville, MD, USA), with 90.8% of purity. HPLC grade methanol was purchased from J. T. Baker Inc. (USA), Acetonitrile from Merck Ltd. (Germany). HPLC grade water was used from Fisher Scientific co. (Korea).
Stock solution for ivermectin was prepared in mobile phase to get concentration of 1,000 μg/mL. Ivermectin standard working solution was prepared in mobile phase at a final concentration of 100 μg/mL. The stock solution was diluted with mobile phase into a series of standard solutions (50, 80, 100, 120 and 150 μg/mL).
Among eleven ivermectin in solutions dosage forms registered with the Animal Drug Association, five commercially available anthelmintic formulations (5 solutions) were selected and purchased except for six formulations (solutions) which production was stopped. Five commercial anthelmintic formulations contain 5 g ivermectin per liter of product. 1 mL of solutions were transferred into a 50 mL volumetric flask each, and filled with mobile phase to obtain a concentration of 100 μg/mL. These samples were sonicated for 15 min and then the samples were filtered using 0.45 μm membrane.
Chromatographic separation was achieved on two mobile phases - water/methanol/acetonitrile (15:34:51, v/v) and water/methanol/acetonitrile (19.5:27.5:53, v/v) using Waters X Bridge C18 column (4.6×150 nm, 5 μm) at a flow rate of 1.0 mL/min, with UV detection at wavelengths 245 nm and 254 nm and a column temperature of 25℃.
System suitability test parameters such as peak area (mAU), retention time (Rt), number of theoretical plates (N) and tailing factor (T) for working solution were determined.
We determined parameters for method validation, including system suitability, linearity, limit of Detection (LOD), limit of quantification (LOQ), precision, accuracy and robustness according to the International Conference on Harmonization (ICH) Guidelines. System suitability was determined by six replicates of standard working solution and evaluated by calculating of the relative standard deviation (RSD) of the peak area, retention time, theoretical plates and tailing factor. Linearity was calculated by plotting peak areas versus five different concentrations (50, 80, 100, 120 and 150 ug/mL) and found out a linear equation with correlation coefficient (R2). LOD and LOQ were calculated to determine the sensitivity of the method. Precision was evaluated for repeatability and intermediate precision. Repeatability was determined by analyzing six replicates of ivermectin standard solution in the range 50, 100 and 150 μg/mL for ivermectin. Intermediate precision was determined by analyzing six replicates of ivermectin standard solution in the range 80, 120 and 120 μg/mL for ivermectin on different days. The precision of an analytical procedure was expressed as RSD %. Accuracy was determined by calculating recovery of ivermectin and conducted by adding known amounts of ivermectin standard to the in three replicates. The percent recovery was calculated by the following formula: recovery (%)= (experimental concentration/actual concentration)×100. The robustness was determined by assaying six replicates of standard solution (100 μg/mL of ivermectin) in minor changes of method parameters such as flow rate, column temperature, wavelength and mobile phase ratio.
Under the attempted chromatographic conditions, the correlation coefficients values were 0.9997 or greater. The concentrations of ivermectin were close to those when tested according to the standard test methods for products, and were within the acceptable ranges (from 90 to 120%) of the labeled amount. The results show that both wavelengths (245 nm and 254 nm) can be used to measure the amount of ivermectin, but at a wavelength of 254 nm, the peak area value is smaller for the same concentration; the peak shape obtained at 245 nm was better. In the case of the mobile phase, the C18 column (4.6×150 nm, 5 μm) was used and the retention time was shorter (16.3 to 16.5 min) for the composition of water/methanol/acetonitrile (15/34/51, v/v), than that of the composition of water/methanol/acetonitrile (19.5/27.5/53, v/v) (26.9 to 27.1 min); consequently, the analysis could be conducted faster (Fig. 1). Therefore, the optimized HPLC chromatographic conditions for the analysis of ivermectin in solution were as follows: mobile phase of water/methanol/acetonitrile (15:34:51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters XBridge C18 column (4.6×150 nm, 5 μm) at a column temperature of 25℃ (Table 1).
Table 1 . Optimized chromatographic conditions
Parameters | Chromatographic conditions |
---|---|
Column | Waters X bridge C 18 4.6×150 mm, 5 μm |
Mobile phase | Water:Methanol:Acetonitrile (15:34:51) |
Wavelength | 245 nm |
Column oven | 25℃ |
Flow rate | 1.0 mL/min |
Injection volume | 20 μL |
apparatus | Agilent 1260 Infinity II series, USA |
The optimization of chromatographic conditions led to more efficient and faster separation of ivermectin from commercial ivermectin topical solutions with different HPLC conditions.
RSD % of peak areas, retention times and tailing factors were less than 1.0. The theoretical plates were >10,000 (Table 2). The values of system suitability parameters were all within the acceptable limits and indicated that the system was suitable for the quantification of ivermectin.
Table 2 . System suitability tests and chromatographic conditions
Parameters | Value* | RSD (%) | Acceptable limit |
---|---|---|---|
Retention time (min) | 16.405 | 0.09 | RSD ≤2 |
Peak area | 3483 | 0.1 | RSD ≤2 |
No. of theoretical plates | 10691 | 0.48 | >2000 |
Tailing factor | 1.020 | 0.52 | ≤2 |
*Mean of six values.
The calibration curve was obtained in the concentration range of 50∼150 μg/mL. The linear regression equation for ivermectin was Y=34.98032x−4.69585 and the correlation coefficient (R2) was 0.99999 (Fig. 2). The correlation coefficient was satisfactory (R2 >0.999) and indicated that this method was reliable for quantitative detection.
Limit of detection (LOD) is the lowest concentration of analyte that can be detected, and limit of quantification (LOQ) is the lowest concentration of analyte that can be quantified with acceptable accuracy and precision. The LOD and LOQ for ivermectin were 0.88 μg/mL and 2.68 μg/mL, respectively (Table 3). The results showed the good sensitivity of the proposed method.
Table 3 . Summary of validation parameters
Parameters | Ivermectin |
---|---|
Linear range (μg/mL) | 50∼150 |
Correlation coefficient (r2) | 0.99999 |
LOD (μg/mL) | 0.88 |
LOQ (μg/mL) | 2.68 |
Intra-day precision (repeatability, RSD %) | 0.09∼0.17 |
Intermediate precision (inter-day precision, RSD %) | 0.07∼0.20 |
Accuracy (% Recovery) | 98.9∼100.3 |
For the accuracy of the method, a recovery test was conducted by adding known amounts of ivermectin standard (80, 100 and 120 μg/mL) to the sample (19.66 μg/mL of ivermectin) and analyzing three replicates. To determine the precision of the method, repeatability (intra-day precision) and intermediate precision (inter-day precision) were evaluated. In this study, the mean recovery rate of ivermectin was 98.9% to 100.3% and the % RSD was not >2% (Table 3), indicating that the method was capable of showing good accuracy and precision.
The values of tailing factor, theoretical plates and % RSD were within the acceptance ranges (Table 4). So, the method was shown to be robust for minor changes in method parameters such as flow rate (±0.1 mL/min), column temperature (±2℃), wavelength (±2 nm) and mobile phase composition (MEOH content ±2% v).
Table 4 . Robustness tests for Ivermectin
Parameters | Variation | Tailing factor | Theoretical plates | |||
---|---|---|---|---|---|---|
Value* | RSD (%) | Value* | RSD (%) | |||
Flow rate (mL/min) | 0.9 | 1.13 | 0.45 | 7225 | 0.49 | |
1.1 | 1.13 | 0.59 | 6577 | 0.55 | ||
Column temperature (℃) | 23 | 1.13 | 0.47 | 7355 | 0.35 | |
27 | 1.14 | 0.63 | 6728 | 0.22 | ||
Detection wavelength (nm) | 243 | 1.14 | 0.47 | 6761 | 0.99 | |
247 | 1.14 | 0.46 | 6757 | 1.00 | ||
Mobile phase composition-Methanol content (% v) | 32 | 1.14 | 0.34 | 7254 | 0.89 | |
36 | 1.13 | 0.42 | 7254 | 0.29 |
*Mean of three values.
The optimized HPLC procedure was applied for the analysis of 5 commercially available products. The contents of ivermectin were found to be in the range from 91.2% to 102.7% and were within the acceptable ranges (90∼120%) for the percent of the labeled amount (Table 5).
Table 5 . Concentration of ivermectin in marketed solutions
Sample No. | Label concentration (g/L) | The standard test method (μg/mL) | The proposed method | |
---|---|---|---|---|
Quantity in sample (μg/mL) | Concentration (%) | |||
1 | 5 | 4.99 | 4.96 | 99.5 |
2 | 5 | 5.11 | 5.13 | 102.7 |
3 | 5 | 4.75 | 4.78 | 95.6 |
4 | 5 | 4.70 | 4.56 | 91.2 |
5 | 5 | 4.80 | 5.08 | 101.5 |
The optimized HPLC chromatographic method was established and validated for the assay of ivermectin in solutions. The results of this study showed that this HPLC method is simple, rapid, accurate, precise, sensitive and robust. Therefore, this method can be performed for routine quality control analysis of ivermectin from commercial ivermectin topical solutions with different HPLC conditions.
This study was supported by research funds from the Animal and Plant Quarantine Agency (APQA), Republic of Korea (Project Code No. N-1543073-2018-22-0104).
No potential conflict of interest relevant to this article was reported.
Korean J. Vet. Serv. 2022; 45(3): 243-248
Published online September 30, 2022 https://doi.org/10.7853/kjvs.2022.45.3.243
Copyright © The Korean Socitety of Veterinary Service.
Young-Wook Kim 1*, Wooseog Jeong
2
1Bacterial Disease Division, Animal and Plant Quarantine Agency, Gimcheon 39660, Korea
2Veterinary Drugs & Biologics Division, Animal and Plant Quarantine Agency, Gimcheon 39660, Korea
Correspondence to:Young-Wook Kim
E-mail: kimyu1223@korea.kr
https://orcid.org/0000-0003-0498-6594
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0). which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
The HPLC conditions for analysis of ivermectin in solutions dosage forms of commercial anthelmintics are different for each product. The purpose of this study was to establish a standardized chromatographic method for the quantification of ivermectin in solution. The separation was achieved on Waters Xbridge C18 column (4.6×150 nm, 5 μm) using different kinds of mobile phase composed of water/methanol/acetonitrile (15/34/51, v/v and 19.5/27.5/53, v/v), with UV detection at wavelengths 245 nm and 254 nm. A total of five commercial ivermectin in solution samples were analyzed. In this study, the optimal chromatographic conditions for analysis of ivermectin in solution were mobile phase of water/methanol/acetonitrile (15/34/51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters Xbridge C18 column (4.6×250 nm, 5 μm) at a column temperature of 25℃. The linearity was observed in the concentration range of 50∼150 μg/mL, with a correlation coefficient, r2=0.99999. The limit of detection and the limit of quantification were 0.88 and 2.68 μg/mL, respectively. The accuracy (% recovery) was found to be 98.9 to 100.3%. Intraday and Intermediate precisions with relative standard deviations were less than 1.0%. The content of ivermectin for five market samples ranged 91.2∼102.7%. The proposed method was also found to be robust, therefore, the method can be used for the routine analysis of ivermectin in solutions dosage forms.
Keywords: Ivermectin, Veterinary, HPLC, Validation
Ivermectin (5-O-dimethyl-22,23-dihydroaverrmectin) is an antiparasitic and anthelmintic agent that kills various parasites such as lice, mange and wireworms etc (Waldia et al, 2008; Patel et al, 2015). It has been used in domestic animals for treatment of endoparasites and ectoparasites (Bark et al, 2007; Rao et al, 2017). Many analytical methods including thin-layer chromatography (TLC), high performance liquid chromatography (HPLC), high performance liquid chromatography with mass-spectrometry (HPLC-MS) or tandem mass spectrometry (MS/MS) have been developed for the analysis of ivermectin (Waldia et al, 2008). Ivermectin can be administered orally, subcutaneously, intramusculary and applied to the skin (Bark et al, 2007). Ivermectin in solution dosage form applied to the skin is easy to use in livestock farms and its use is increasing day by day (Bark et al, 2007). Currently, there are 11 ivermectin topical solutions from 11 companies registered with the Animal Drug Associations (based on sales performance from 2010 to 2019). All 11 products use HPLC to quantify ivermectin. However, the HPLC conditions such as mobile phase, flow rate and wavelength are different for each product, quality control is not performed with the same test method.
Therefore, we aimed to establish a standardized chromatographic method for the quantification of ivermectin in solution and validate the established assay.
Agilent 1260 Infinity II series HPLC system equipped with a model G7111A pump, a model G7129A autosampler, a model G7117C UV-detector and Chemstation Software (Version Rev C.01.10 (236)) were used.
Ivermectin was purchased from the United States Pharmacopeia (USP) (Rockville, MD, USA), with 90.8% of purity. HPLC grade methanol was purchased from J. T. Baker Inc. (USA), Acetonitrile from Merck Ltd. (Germany). HPLC grade water was used from Fisher Scientific co. (Korea).
Stock solution for ivermectin was prepared in mobile phase to get concentration of 1,000 μg/mL. Ivermectin standard working solution was prepared in mobile phase at a final concentration of 100 μg/mL. The stock solution was diluted with mobile phase into a series of standard solutions (50, 80, 100, 120 and 150 μg/mL).
Among eleven ivermectin in solutions dosage forms registered with the Animal Drug Association, five commercially available anthelmintic formulations (5 solutions) were selected and purchased except for six formulations (solutions) which production was stopped. Five commercial anthelmintic formulations contain 5 g ivermectin per liter of product. 1 mL of solutions were transferred into a 50 mL volumetric flask each, and filled with mobile phase to obtain a concentration of 100 μg/mL. These samples were sonicated for 15 min and then the samples were filtered using 0.45 μm membrane.
Chromatographic separation was achieved on two mobile phases - water/methanol/acetonitrile (15:34:51, v/v) and water/methanol/acetonitrile (19.5:27.5:53, v/v) using Waters X Bridge C18 column (4.6×150 nm, 5 μm) at a flow rate of 1.0 mL/min, with UV detection at wavelengths 245 nm and 254 nm and a column temperature of 25℃.
System suitability test parameters such as peak area (mAU), retention time (Rt), number of theoretical plates (N) and tailing factor (T) for working solution were determined.
We determined parameters for method validation, including system suitability, linearity, limit of Detection (LOD), limit of quantification (LOQ), precision, accuracy and robustness according to the International Conference on Harmonization (ICH) Guidelines. System suitability was determined by six replicates of standard working solution and evaluated by calculating of the relative standard deviation (RSD) of the peak area, retention time, theoretical plates and tailing factor. Linearity was calculated by plotting peak areas versus five different concentrations (50, 80, 100, 120 and 150 ug/mL) and found out a linear equation with correlation coefficient (R2). LOD and LOQ were calculated to determine the sensitivity of the method. Precision was evaluated for repeatability and intermediate precision. Repeatability was determined by analyzing six replicates of ivermectin standard solution in the range 50, 100 and 150 μg/mL for ivermectin. Intermediate precision was determined by analyzing six replicates of ivermectin standard solution in the range 80, 120 and 120 μg/mL for ivermectin on different days. The precision of an analytical procedure was expressed as RSD %. Accuracy was determined by calculating recovery of ivermectin and conducted by adding known amounts of ivermectin standard to the in three replicates. The percent recovery was calculated by the following formula: recovery (%)= (experimental concentration/actual concentration)×100. The robustness was determined by assaying six replicates of standard solution (100 μg/mL of ivermectin) in minor changes of method parameters such as flow rate, column temperature, wavelength and mobile phase ratio.
Under the attempted chromatographic conditions, the correlation coefficients values were 0.9997 or greater. The concentrations of ivermectin were close to those when tested according to the standard test methods for products, and were within the acceptable ranges (from 90 to 120%) of the labeled amount. The results show that both wavelengths (245 nm and 254 nm) can be used to measure the amount of ivermectin, but at a wavelength of 254 nm, the peak area value is smaller for the same concentration; the peak shape obtained at 245 nm was better. In the case of the mobile phase, the C18 column (4.6×150 nm, 5 μm) was used and the retention time was shorter (16.3 to 16.5 min) for the composition of water/methanol/acetonitrile (15/34/51, v/v), than that of the composition of water/methanol/acetonitrile (19.5/27.5/53, v/v) (26.9 to 27.1 min); consequently, the analysis could be conducted faster (Fig. 1). Therefore, the optimized HPLC chromatographic conditions for the analysis of ivermectin in solution were as follows: mobile phase of water/methanol/acetonitrile (15:34:51, v/v) at a flow rate of 1.0 mL/min and a detection wavelength of 245 nm using a Waters XBridge C18 column (4.6×150 nm, 5 μm) at a column temperature of 25℃ (Table 1).
Table 1 . Optimized chromatographic conditions.
Parameters | Chromatographic conditions |
---|---|
Column | Waters X bridge C 18 4.6×150 mm, 5 μm |
Mobile phase | Water:Methanol:Acetonitrile (15:34:51) |
Wavelength | 245 nm |
Column oven | 25℃ |
Flow rate | 1.0 mL/min |
Injection volume | 20 μL |
apparatus | Agilent 1260 Infinity II series, USA |
The optimization of chromatographic conditions led to more efficient and faster separation of ivermectin from commercial ivermectin topical solutions with different HPLC conditions.
RSD % of peak areas, retention times and tailing factors were less than 1.0. The theoretical plates were >10,000 (Table 2). The values of system suitability parameters were all within the acceptable limits and indicated that the system was suitable for the quantification of ivermectin.
Table 2 . System suitability tests and chromatographic conditions.
Parameters | Value* | RSD (%) | Acceptable limit |
---|---|---|---|
Retention time (min) | 16.405 | 0.09 | RSD ≤2 |
Peak area | 3483 | 0.1 | RSD ≤2 |
No. of theoretical plates | 10691 | 0.48 | >2000 |
Tailing factor | 1.020 | 0.52 | ≤2 |
*Mean of six values..
The calibration curve was obtained in the concentration range of 50∼150 μg/mL. The linear regression equation for ivermectin was Y=34.98032x−4.69585 and the correlation coefficient (R2) was 0.99999 (Fig. 2). The correlation coefficient was satisfactory (R2 >0.999) and indicated that this method was reliable for quantitative detection.
Limit of detection (LOD) is the lowest concentration of analyte that can be detected, and limit of quantification (LOQ) is the lowest concentration of analyte that can be quantified with acceptable accuracy and precision. The LOD and LOQ for ivermectin were 0.88 μg/mL and 2.68 μg/mL, respectively (Table 3). The results showed the good sensitivity of the proposed method.
Table 3 . Summary of validation parameters.
Parameters | Ivermectin |
---|---|
Linear range (μg/mL) | 50∼150 |
Correlation coefficient (r2) | 0.99999 |
LOD (μg/mL) | 0.88 |
LOQ (μg/mL) | 2.68 |
Intra-day precision (repeatability, RSD %) | 0.09∼0.17 |
Intermediate precision (inter-day precision, RSD %) | 0.07∼0.20 |
Accuracy (% Recovery) | 98.9∼100.3 |
For the accuracy of the method, a recovery test was conducted by adding known amounts of ivermectin standard (80, 100 and 120 μg/mL) to the sample (19.66 μg/mL of ivermectin) and analyzing three replicates. To determine the precision of the method, repeatability (intra-day precision) and intermediate precision (inter-day precision) were evaluated. In this study, the mean recovery rate of ivermectin was 98.9% to 100.3% and the % RSD was not >2% (Table 3), indicating that the method was capable of showing good accuracy and precision.
The values of tailing factor, theoretical plates and % RSD were within the acceptance ranges (Table 4). So, the method was shown to be robust for minor changes in method parameters such as flow rate (±0.1 mL/min), column temperature (±2℃), wavelength (±2 nm) and mobile phase composition (MEOH content ±2% v).
Table 4 . Robustness tests for Ivermectin.
Parameters | Variation | Tailing factor | Theoretical plates | |||
---|---|---|---|---|---|---|
Value* | RSD (%) | Value* | RSD (%) | |||
Flow rate (mL/min) | 0.9 | 1.13 | 0.45 | 7225 | 0.49 | |
1.1 | 1.13 | 0.59 | 6577 | 0.55 | ||
Column temperature (℃) | 23 | 1.13 | 0.47 | 7355 | 0.35 | |
27 | 1.14 | 0.63 | 6728 | 0.22 | ||
Detection wavelength (nm) | 243 | 1.14 | 0.47 | 6761 | 0.99 | |
247 | 1.14 | 0.46 | 6757 | 1.00 | ||
Mobile phase composition-Methanol content (% v) | 32 | 1.14 | 0.34 | 7254 | 0.89 | |
36 | 1.13 | 0.42 | 7254 | 0.29 |
*Mean of three values..
The optimized HPLC procedure was applied for the analysis of 5 commercially available products. The contents of ivermectin were found to be in the range from 91.2% to 102.7% and were within the acceptable ranges (90∼120%) for the percent of the labeled amount (Table 5).
Table 5 . Concentration of ivermectin in marketed solutions.
Sample No. | Label concentration (g/L) | The standard test method (μg/mL) | The proposed method | |
---|---|---|---|---|
Quantity in sample (μg/mL) | Concentration (%) | |||
1 | 5 | 4.99 | 4.96 | 99.5 |
2 | 5 | 5.11 | 5.13 | 102.7 |
3 | 5 | 4.75 | 4.78 | 95.6 |
4 | 5 | 4.70 | 4.56 | 91.2 |
5 | 5 | 4.80 | 5.08 | 101.5 |
The optimized HPLC chromatographic method was established and validated for the assay of ivermectin in solutions. The results of this study showed that this HPLC method is simple, rapid, accurate, precise, sensitive and robust. Therefore, this method can be performed for routine quality control analysis of ivermectin from commercial ivermectin topical solutions with different HPLC conditions.
This study was supported by research funds from the Animal and Plant Quarantine Agency (APQA), Republic of Korea (Project Code No. N-1543073-2018-22-0104).
No potential conflict of interest relevant to this article was reported.
Table 1 . Optimized chromatographic conditions.
Parameters | Chromatographic conditions |
---|---|
Column | Waters X bridge C 18 4.6×150 mm, 5 μm |
Mobile phase | Water:Methanol:Acetonitrile (15:34:51) |
Wavelength | 245 nm |
Column oven | 25℃ |
Flow rate | 1.0 mL/min |
Injection volume | 20 μL |
apparatus | Agilent 1260 Infinity II series, USA |
Table 3 . Summary of validation parameters.
Parameters | Ivermectin |
---|---|
Linear range (μg/mL) | 50∼150 |
Correlation coefficient (r2) | 0.99999 |
LOD (μg/mL) | 0.88 |
LOQ (μg/mL) | 2.68 |
Intra-day precision (repeatability, RSD %) | 0.09∼0.17 |
Intermediate precision (inter-day precision, RSD %) | 0.07∼0.20 |
Accuracy (% Recovery) | 98.9∼100.3 |
Table 4 . Robustness tests for Ivermectin.
Parameters | Variation | Tailing factor | Theoretical plates | |||
---|---|---|---|---|---|---|
Value* | RSD (%) | Value* | RSD (%) | |||
Flow rate (mL/min) | 0.9 | 1.13 | 0.45 | 7225 | 0.49 | |
1.1 | 1.13 | 0.59 | 6577 | 0.55 | ||
Column temperature (℃) | 23 | 1.13 | 0.47 | 7355 | 0.35 | |
27 | 1.14 | 0.63 | 6728 | 0.22 | ||
Detection wavelength (nm) | 243 | 1.14 | 0.47 | 6761 | 0.99 | |
247 | 1.14 | 0.46 | 6757 | 1.00 | ||
Mobile phase composition-Methanol content (% v) | 32 | 1.14 | 0.34 | 7254 | 0.89 | |
36 | 1.13 | 0.42 | 7254 | 0.29 |
*Mean of three values..
Table 5 . Concentration of ivermectin in marketed solutions.
Sample No. | Label concentration (g/L) | The standard test method (μg/mL) | The proposed method | |
---|---|---|---|---|
Quantity in sample (μg/mL) | Concentration (%) | |||
1 | 5 | 4.99 | 4.96 | 99.5 |
2 | 5 | 5.11 | 5.13 | 102.7 |
3 | 5 | 4.75 | 4.78 | 95.6 |
4 | 5 | 4.70 | 4.56 | 91.2 |
5 | 5 | 4.80 | 5.08 | 101.5 |
Kim, Young-Wook;Han, Bok Hee;Kang, Young Eun;Rhee, Chae Hong;Seo, Sang-Ji;Kim, Soohee;Jeong, Wooseog;Her, Moon;
Korean J. Vet. Serv. 2020; 43(4): 261-265 https://doi.org/10.7853/kjvs.2020.43.4.261Koh Ba-Ra-Da;Park Seong-Do;Jang Mi-Sun;Na Ho-Myung;Kim Yong-Hwan;
Korean J. Vet. Serv. 2005; 28(3): 235-243 https://doi.org/10.7853/.2005.28.3.235Seo Hee-Jin;Lee Yeong-Mi;Do Jae-Cheul;Park No-Chan;Lee Yang-Soo;
Korean J. Vet. Serv. 2006; 29(3): 331-338 https://doi.org/10.7853/.2006.29.3.331